FORE-DAMAGE STATE OF STEEL FRAME WITH DEFECTIVE FIELD SPLICES

Article Abstract by: toffi_75    

Original Authors: Marian Gwóźdź; Andrzej Machowski; Paweł Żwirek
Some
field welded joints ultrasonic and magnetic partele inspection had been made
during technological modernization
of industrial building steel frame. Welded
joints quality assessments obtained from two different laboratories were
negative. Fundamental quality requirements weren’t fullfiled yet from 1995 year
when the object was finished and exploitation was started. During ordered
complex investigations some significant for building safety departures from the
execution project were constated. In time of the integration of steel frame
field splices in lateral frames girders were displaced to nodes in area of
extreme cross-sectional forces.